Reference number
ISO 2599:1983
ISO 2599:1983
Iron ores — Determination of phosphorus content — Titrimetric method
Edition 2
1983-11
Retirada
ISO 2599:1983
7584
Retirada (Edición 2, 1983)

Resumen

This second edition cancels and replaces the first edition (i.e. ISO 2599:1973). Specifies a method using hexaammonium heptamolybdate (ammonium molybdate). The method is applicable to a concentration range of 0,10 to 5,0 % (m/m) of phosphorus in natural iron ores, and iron ore concentrates and agglomerates, including sinter products. Describes principle, reagents, apparatus, sampling and samples, procedure, expression of results and test report.

Informaciones generales

  •  : Retirada
     : 1983-11
    : Retirada de la Norma Internacional [95.99]
  •  : 2
     : 8
  • ISO/TC 102/SC 2
    73.060.10 
  • RSS actualizaciones

¿Tiene alguna duda?

Consulte nuestras Ayuda y asistencia