Raccords en poly(chlorure de vinyle) non plastifié (PVC-U) moulés par injection — Essai à l'étuve — Méthode d'essai et spécifications de base
Edition 2
1990-11
Annulée
ISO 580:1990
4676
Annulée (Edition 2, 1990)

Résumé

The test can be used to determine whether cold slug or unfused areas are present, to determine the amount of moulded-in stress produced by the moulding process, reveal contamination and to show the quality of the weld. Complete fittings are subjected to a temperature of 150° centigrade in an air-circulating oven for a given time depending on the wall thickness of the fitting. The surfaces of the fitting are examined before and after heating. Cracks, blisters,*delamination or weld opening is measured, expressed as a percentage of the wall thickness.