Filter :
Standard and/or project under the direct responsibility of ISO/TC 138/SC 2 Secretariat | Stage | ICS |
---|---|---|
Unplasticized polyvinyl chloride (PVC) fittings with plain sockets for pipes under pressure — Laying lengths — Metric series |
95.99 | |
Unplasticized polyvinyl chloride (PVC) fittings with plain sockets for pipes under pressure — Laying lengths — Metric series — Addendum 1: Diameters 200 mm and 225 mm |
95.99 | |
Fittings made from unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure — Part 1: Metric series |
90.93 | |
Fittings made from unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure — Part 2: Inch-based series |
95.99 | |
Fittings made from unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure — Part 2: Inch-based series |
90.93 | |
Fittings of unplasticized polyvinyl chloride (PVC-U), chlorinated polyvinyl chloride (PVC-C) or acrylonitrile/butadiene/styrene (ABS) with plain sockets for pipes under pressure — Dimensions of sockets — Metric series |
95.99 | |
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: General |
90.93 | |
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes |
90.93 | |
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 3: Fittings |
90.93 | |
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 4: Valves |
90.93 | |
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system |
90.93 | |
Single sockets for unplasticized poly(vinyl chloride) (PVC-U) and chlorinated poly (vinyl chloride) (PVC-C) pressure pipes with elastic sealing ring type joints — Minimum depths of engagement |
95.99 | |
Double-socket fittings for unplasticized poly(vinyl chloride) (PVC-U) pressure pipes with elastic sealing ring type joints — Minimum depths of engagement |
95.99 | |
Unplasticized polyvinyl chloride (PVC) pressure pipes and fittings, metric series — Dimensions of flanges |
95.99 | |
Assembled joints between fittings and polyethylene (PE) pressure pipes — Test of leakproofness under internal pressure |
95.99 | |
Polyethylene (PE) pressure pipes — Joints assembled with mechanical fittings — Internal under-pressure test method and requirement |
95.99 | |
Unplasticized polyvinyl chloride (PVC) pressures pipes — Metric series — Dimensions of adapter for backing flange |
95.99 | |
Assembled joints between fittings and polyethylene (PE) pressure pipes — Test of resistance to pull out |
95.99 | |
Assembled joints between fittings and polyethylene (PE) pressure pipes — Test of leakproofness under internal pressure when subjected to bending |
95.99 | |
Fittings for unplasticized polyvinyl chloride (PVC) pressure pipes with elastic sealing ring type joints — Pressure test for leakproofness |
90.93 | |
Fittings for unplasticized polyvinyl chloride (PVC) pressure pipes with elastic sealing ring type joints — Pressure test for leakproofness under conditions of external hydraulic pressure |
95.99 | |
Polyethylene (PE) pressure pipes and fittings, metric series — Dimensions of flanges |
95.99 | |
Unplasticized polyvinyl chloride (PVC) and metal adaptor fittings for pipes under pressure — Laying lengths and size of threads — Metric series |
90.93 | |
Unplasticized polyvinyl chloride (PVC-U) pipes for water supply — Recommended practice for laying |
95.99 | |
Plastics piping systems for water supply — Unplasticized poly(vinyl chloride)(PVC-U) and oriented PVC-U (PVC-O) — Guidance for installation |
90.93 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Part 1: General |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Part 2: Pipes (with or without integral sockets) |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Part 3: Fittings and joints |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Part 4: Valves and ancillary equipment |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Part 5: Fitness for purpose of the system |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications |
95.99 | |
Pipes and fittings made of unplasticized poly(vinyl chloride) (PVC-U) for water supply — Specifications — Amendment 1 |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 1: General |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 1: General — Amendment 1: Melt mass-flow rate (MFR) for PE 80 and PE 100 |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 1: General — Technical Corrigendum 1 |
95.99 | |
Plastics piping systems for water supply and for drainage and sewerage under pressure — Polyethylene (PE) — Part 1: General |
60.60 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 2: Pipes |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 2: Pipes — Amendment 1 |
95.99 | |
Plastics piping systems for water supply, and for drainage and sewerage under pressure — Polyethylene (PE) — Part 2: Pipes |
60.60 | |
Plastics piping systems for water supply, and for drainage and sewerage under pressure — Polyethylene (PE) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 3: Fittings |
95.99 | |
Plastics piping systems for water supply, and for drainage and sewerage under pressure — Polyethylene (PE) — Part 3: Fittings |
60.60 | |
Plastics piping systems — Polyethylene (PE) pipes and fittings for water supply — Part 5: Fitness for purpose of the system |
95.99 | |
Plastics piping systems for water supply, and for drainage and sewerage under pressure — Polyethylene (PE) — Part 5: Fitness for purpose of the system |
60.60 | |
Polyethylene (PE) pipes for water supply — Specifications |
95.99 | |
Unplasticized polyvinyl chloride (PVC) adaptor fittings for pipes under pressure — Laying length and size of threads — Metric series |
95.99 | |
Unplasticized polyvinyl chloride (PVC) fittings with elastic sealing ring type joints for pipes under pressure — Dimensions of laying lengths — Metric series |
95.99 | |
Polypropylene (PP) fittings for pipes under pressure — Sockets for fusion using heated tools — Metric series — Dimensions of sockets |
95.99 | |
Polyethylene (PE) pipes for irrigation laterals — Specifications |
95.99 | |
Polyethylene (PE) pipes for irrigation laterals — Specifications |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes for irrigation — Specifications |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes for irrigation — Specifications — Amendment 1 |
95.99 | |
Plastics piping systems — Polyethylene (PE) pipes for irrigation — Specifications |
60.60 | |
Polyethylene (PE) 25 pipes for irrigation laterals — Susceptibility to environmental stress-cracking induced by insert-type fittings — Test method and specification |
95.99 | |
Polyethylene PE 32 and PE 40 pipes for irrigation laterals — Susceptibility to environmental stress cracking induced by insert-type fittings — Test method and requirements |
90.93 | |
PE/metal and PP/metal adaptor fittings for pipes for fluids under pressure — Design lengths and size of threads — Metric series |
90.93 | |
Thermoplastics pipes for fluids under pressure — Mating dimensions of flange adapters and loose backing flanges |
95.99 | |
Thermoplastics piping systems for fluids under pressure — Flange adapters and loose backing flanges — Mating dimensions |
60.60 | |
Thermoplastics piping systems for fluids under pressure — Flange adapters and loose backing flanges — Mating dimensions — Amendment 1 |
60.60 | |
Mechanical joint fittings for use with polyethylene pressure pipes for irrigation purposes |
95.99 | |
Thermoplastics pipes for the transport of liquids under pressure — Calculation of head losses |
90.93 | |
Thermoplastics pipes and fittings for hot and cold water systems |
95.99 | |
Plastics piping systems for hot and cold water installations — Guidance for classification and design |
90.93 | |
Plastics piping systems for hot and cold water installations — Guidance for classification and design — Amendment 1 |
60.60 | |
Plastics piping systems for water supply and drainage and sewerage under pressure — high impact resistant poly(vinyl chloride) (PVC-HI) pipe |
20.20 |
|
Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure |
90.93 | |
Plastics piping systems — Elastomeric-sealing-ring-type socket joints of unplasticized poly(vinyl chloride) (PVC-U) for use with PVC-U pipes — Test method for leaktightness under negative pressure |
95.99 | |
Plastics piping systems — Elastomeric-sealing-ring-type socket joints for use with unplasticized poly(vinyl chloride) (PVC-U) pipes — Test method for leaktightness under internal pressure and with angular deflection |
95.99 | |
Plastics piping systems — End-load-bearing and non-end-load-bearing assemblies and joints for thermoplastics pressure piping — Test method for long-term leaktightness under internal water pressure |
90.93 | |
Plastics pipes and fittings — Mechanical-joint compression fittings for use with polyethylene pressure pipes in water supply systems |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 1: General |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 1: General — Amendment 1 |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 1: General |
90.93 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 1: General — Amendment 1: Impact test |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes — Amendment 1 |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes |
90.93 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 2: Pipes — Amendment 2: Impact test |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 3: Fittings |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 3: Fittings |
90.93 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 3: Fittings — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 3: Fittings — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 5: Fitness for purpose of the system |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 5: Fitness for purpose of the system |
90.93 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 5: Fitness for purpose of the system — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Polypropylene (PP) — Part 7: Guidance for the assessment of conformity |
90.93 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 1: General |
90.92 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 1: General — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 1: General |
30.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 2: Pipes |
90.92 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 2: Pipes — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 2: Pipes |
30.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 3: Fittings |
90.92 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 3: Fittings — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 3: Fittings — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 3: Fittings |
30.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 5: Fitness for purpose of the system |
90.92 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 5: Fitness for purpose of the system — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 5: Fitness for purpose of the system — Technical Corrigendum 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 5: Fitness for purpose of the system |
30.60 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Crosslinked polyethylene (PE-X) — Part 7: Guidance for the assessment of conformity |
90.93 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 1: General |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 1: General — Amendment 1 |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 1: General |
90.93 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 2: Pipes |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 2: Pipes — Amendment 1 |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 2: Pipes |
90.93 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 3: Fittings |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 3: Fittings |
90.93 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 3: Fittings — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 3: Fittings — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 5: Fitness for purpose of the system |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 5: Fitness for purpose of the system |
90.93 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 5: Fitness for purpose of the system — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polybutylene (PB) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Polybutene (PB) — Part 7: Guidance for the assessment of conformity |
90.93 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 1: General |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 1: General |
90.93 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 1: General — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 2: Pipes |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 2: Pipes |
90.93 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 2: Pipes — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 3: Fittings |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 3: Fittings |
90.93 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 3: Fittings — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 3: Fittings — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 5: Fitness for purpose of the system |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 5: Fitness for purpose of the system |
90.93 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 5: Fitness for purpose of the system — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 5: Fitness for purpose of the system — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Chlorinated poly(vinyl chloride) (PVC-C) — Part 7: Guidance for the assessment of conformity |
90.93 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 1: General |
50.00 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 2: Pipes |
50.00 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 3: Fittings |
60.60 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Part 5: Fitness for purpose of the system |
50.00 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Specifications |
95.99 | |
Pipes and joints made of oriented unplasticized poly(vinyl chloride) (PVC-O) for the conveyance of water under pressure — Specifications |
90.92 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 1: General |
90.93 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 2: Pipes |
90.93 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 2: Pipes — Amendment 1 |
60.60 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 3: Fittings |
90.93 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 3: Fittings — Amendment 1 |
60.60 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 5: Fitness for purpose of the system |
90.93 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 7: Guidance for the assessment of conformity |
95.99 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 7: Guidance for the assessment of conformity — Amendment 1 |
95.99 | |
Multilayer piping systems for hot and cold water installations inside buildings — Part 7: Guidance for the assessment of conformity |
90.93 | |
Plastics piping systems — Multilayer pipes and their joints, based on thermoplastics, for water supply |
90.93 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 1: General |
95.99 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 1: General |
90.93 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 2: Pipes |
95.99 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 2: Pipes |
90.93 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 2: Pipes — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 3: Fittings |
95.99 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 3: Fittings |
90.93 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 3: Fittings — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 3: Fittings — Amendment 2 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 5: Fitness for purpose of the system |
95.99 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 5: Fitness for purpose of the system |
90.93 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 5: Fitness for purpose of the system — Amendment 1 |
60.60 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 7: Guidance for the assessment of conformity |
95.99 | |
Plastics piping systems for hot and cold water installations — Polyethylene of raised temperature resistance (PE-RT) — Part 7: Guidance for the assessment of conformity |
90.93 | |
Thermoplastics piping systems - Guidance for definitions of wall constructions for pipes |
90.93 |
No matching records found. Please try changing the filter settings.