Abstract
Specifies a test method for the determination of particle size distribution by sieving. The procedure includes weighing out a test portion of 100 g of the sample, placing the test portion in the top sieve of a set of test sieves (including all the sieves listed against the grade under test in the appropriate part of ISO 11124) with the largest-aperture sieve on the top and progress to the smallest aperture at the bottom with a pan, to catch any abrasive that falls through the finest sieve, sieving in a sieve machine, weighing the abrasive retained on each sieve and transferred on to a balance pan. Annex A gives information on the international standards series for non-metallic blast-cleaning abrasives ISO 11124 and ISO 11125.
-
Status: WithdrawnPublication date: 1993-12
-
Edition: 1Number of pages: 4
-
Technical Committee: ISO/TC 35/SC 12 Preparation of steel substrates before application of paints and related products
-
- ICS :
- 25.220.10 Surface preparation