Abstract
Specifies a method for the determination of the ash unplasticized cellulose acetate, free of additives, fillers, dyes or other materials, which may affect the result. -Ignition of a test portion and calcination in a muffle furnace maintained at 575 C or 850 C (as agreed). Higher temperatures such as 850 C will convert carbonates to the oxides and thus give lower values. The general instructions in ISO 3451/1 shall be followed.
General information
-
Status: PublishedPublication date: 1984-05Stage: International Standard confirmed [90.93]
-